D1xC1X10R Radial Alarm Horn & Xenon Strobe

The D1xC1X05R is a high output 115dB(A) alarm horn with omni-directional radial horn a & 10 Joule Xenon strobe. The robust Type 4/4X, IP66 marine grade, corrosion proof LM6 enclosure ensures suitability for all Class I Div 1 & Zone 1 applications.

es2 safety badges es2 safety badges es2 safety badges es2 safety badges es2 safety badges es2 safety badges es2 safety badges
The alarm horn & Xenon strobe allow simultaneous or independent operation. Featuring 64 first stage/channel alarm sounds, the alarm tone frequencies for the first 2 stages are independently selectable. Each of the available 4 stage/channels can be remotely triggered e.g. via an external relay. The DC version is approved for public mode fire alarm use (alarm horn) and private mode fire alarm use (strobe beacon).
  • Automatic synchronisation on multi sounder systems.
  • User selectable strobe flash rates – dual Xenon flash tubes
  • Ratchet adjustable stainless steel ‘U’ bracket.
  • High output omni-directional alarm horn, up to 115dB(A)
  • Xenon strobe – private mode fire alarm use
  • Alarm horn – public mode fire alarm use
  • 4 remotely selectable alarm stages/channels
  • Positive or negative line stage/channel switching
  • Choice of 64 alarm tone frequencies
  • Compact form factor
  • Robust corrosion proof aluminium enclosure
  • Stainless steel fixings
  • Triple cable entries
  • Duplicate cable terminations
Alarm Horn:
Maximum output: 115dB(A) @ 1 metre [106dB(A) @ 10ft/3m]
Nominal output: 110dB(A) @ 1m +/- 3dB – Tone 2 [101dB(A) @ 10ft/3m]
No. of tones: 64 (UKOOA / PFEER compliant)
No. of stages: 4
Volume control: Adjustable -12dB(A)
Effective range: 125m/410ft @ 1KHz
Supply Voltages: 24Vdc; 115Vac; 230Vac
Stage switching: DC units: negative or positive
AC units: common supply line
Strobe Beacon:
Energy: 10 Joules (10Ws)
Flash rates: Option 1: 1Hz (60 fpm)
Option 2: 1.5Hz (90 fpm)
Option 3: Double Strike
Peak Candela: 1,000,000 cd – calculated from energy (J)
Effective Intensity: 500 cd – calculated from energy (J)
Peak Candela: 85,544 cd* – measured ref. to I.E.S.
Effective Intensity: 260 cd* – measured ref. to I.E.S.
Lens colours: Amber, Blue, Clear, Green, Magenta, Red & Yellow
Tube life : Emissions are reduced to 70% after 5 million flashes
General:
Ingress protection: EN60529: IP66
UL50E / NEMA250: 4 / 4X / 3R / 13
Enclosure material: Marine grade aluminium LM6- copper free
Chromated & powder coated – corrosion proof
Colour: Red (RAL3000), Grey (RAL7038)
Cable entries: 1 × 1/2"NPT & 2 x M20 x 1.5mm
1 × 1/2"NPT & 2 × 1/2"NPT
1 × 1/2"NPT & 2 × 3/4"NPT
Terminals: 0.5 – 2.5mm² (20-14 AWG)
Grounding stud: M5
Operating temp: 24Vdc & 115Vac: -40° to +70°C [-40° to +158°F]
230Vac: -40° to +55°C [-40° to +131°F]
Storage temp: -50° to +70°C [-58° to +158°F]
Relative humidity: 95% – Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist
Weight: 4.9kg/10.9lbs
Voltage: Range: Alarm Horn Xenon Strobe Combined
24V dc 20-28Vdc 217mA 673mA 890mA
115V ac 110-120Vac
50/60Hz
76mA 247mA 323mA
230V ac 220-240Vac
50/60Hz
53mA 120mA 173mA
Version: Part code:
Product type: D1xC1X10
Horn type: R Omni-directional radial horn
Voltage: DC024
AC115
AC230
20-28V dc
110-120V ac
220-240V ac
Cable Entry Type:[e] A
B
C
1 × 1/2"NPT & 2 x M20 x 1.5mm
1 × 1/2"NPT & 2 × 1/2"NPT
1 × 1/2"NPT & 2 × 3/4"NPT
Adaptor/Stopping
plug material: [m]
B
N
S
Brass
Nickel Plated
Stainless Steel
Bracket/Guard matl & tag: [s] 1
2
3
4
A2 304 Stainless Steel
A4 316 Stainless Steel
A2 304 St/St with Equip. Tag
A4 316 St/St with Equip. Tag
Product version: [v] A1 Gas environments Class I/Zone1
Enclosure colour: [x] G
R
Grey RAL7038
Red RAL3000
Lens colour: [y] A, B, C, G
M, R, Y
Amber, Blue, Clear, Green
Magenta, Red, Yellow
Accessories: SP65-0001-A2
SP65-0001-A4
SP65-0003-A2
SP65-0003-A4
Pole Mount Bracket Kit 2" St/St A2 (304)
Pole Mount Bracket Kit 2" St/St A4 (316)
Sunshade – St/St A2 (304)
Sunshade – St/St A4 (316)
  • UL File ref: E230764
    UL1203 Ed. 5
    CAN/CSA C22.2 No. 25-1966
    CSA C22.2 No. 30-M1986
    CSA C22.2 No. 205-12
    UL464 Ed. 9
    UL1638 Ed. 4
  • CSFM listing: 7136-2279:0506
  • A1: Gas version
    NEC / CEC:
    Class I Div 1 ABCD T5/T6 Ta -40°C to +55/+50°C
    Class I Div 2 ABCD T5/T6 Ta -40°C to +55/+50°C
    Class I Zone 1, 2 IIC T5/T6 Ta -40°C to +55/+50°C
  • Protection concept: Ex d / AEx d
Amber Blue Clear Green Red Yellow
0.70 0.24 1.00 0.25 0.23 0.93
Stage 1 WAV file Frequency Description. Stage 2 Stage 3 Stage 4
T1 1000 Continuous PFEER Toxic Gas Any T2 T44
T2 1200/500 @ 1Hz Sweeping DIN/PFEER P.T.A.P. Any T3 T44
T3 1000 @ 0.5Hz (1s on, 1s off) Intermittent PFEER Gen. Alarm Any T2 T44
T4 1.4KH-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s NF C 48-265 Any T24 T1
T5 544(100mS)/440 (400mS) NF S 32-001 Any T19 T1
T6 1500/500 – (0.5s on , 0.5s off) x3 + 1s gap AS4428 Any T44 T1
T7 500-1500Hz Sweeping 2 sec on 1 sec off AS4428 Any T44 T1
T8 500/1200Hz @ 0.26Hz(3.3s on, 0.5s off) NEN 2575 Any T24 T35
T9 1000 (1s on, 1s off)x7 + (7s on, 1s off) IMO Code 1a Any T34 T1
T10 1000 (1s on, 1s off)x7 + (7s on, 1s off) IMO Code 1a Any T34 T1
T11 420(0.5s on, 0.5s off)x3 + 1s gap ISO 8201 Temporal Any T1 T8
T12 1000(0.5s on, 0.5s off)x3 + 1s gap ISO 8201 Temporal Any T1 T8
T13 422/775 (0.85 on, 0.5 off) x3 + 1s gap NFPA Temporal Any T1 T8
T14 1000/2000 @ 1Hz – Singapore Any T3 T35
T15 300 Continuous Any T24 T35
T16 440 Continuous Any T24 T35
T17 470 Continuous Any T24 T35
T18 500 Continuous IMO code 2 (Low) Any T24 T35
T19 554 Continuous Any T24 T35
T20 660 Continuous Any T24 T35
T21 800 Continuous IMO code 2 (High) Any T24 T35
T22 1200 Continuous Any T24 T35
T23 2000 Continuous Any T3 T35
T24 2400 Continuous Any T20 T35
T25 440 @ 0.83Hz (0.60s on, 0.60s off) Intermittent Any T44 T8
T26 470 @ 0.9Hz (0.55s on, 0.55s off) Intermittent Any T44 T8
T27 470 @ 5Hz (0.10s on, 0.10s off) Intermittent Any T44 T8
T28 544 @ 1.14Hz (0.43s on, 0.44s off) Intermittent Any T24 T8
T29 655 @ 0.875Hz (0.57s on, 0.57s off) Intermittent Any T44 T8
T30 660 @ 0.28Hz (1.80s on, 1.80s off) Intermittent Any T24 T8
T31 660 @ 3.3Hz (0.15s on, 0.15s off) Intermittent Any T24 T8
T32 745 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T24 T8
T33 800 (0.25s on, 1.00s off) Intermittent Any T24 T8
T34 800 @ 2Hz (0.25s on, 0.25s off) IMO code 3.a (High) Any T24 T8
T35 1000 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T24 T8
T36 2400 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T24 T8
T37 2900 @ 5Hz (0.10s on, 0.10s off) Intermittent Any T24 T8
T38 363/518 @ 1Hz (0.50s/0.50s) Alternating Any T8 T19
T39 450/500 @ 2Hz (0.25s/0.25s) Alternating Any T8 T19
T40 554/440 @ 1Hz (0.50s/0.50s) Alternating Any T24 T19
T41 554/440 @ 0.65Hz (0.76s/0.76s) Alternating Any T8 T19
T42 561/760 @ 0.83Hz (0.60s/0.60s) Alternating Any T8 T19
T43 780/600 @ 0.96Hz (0.52s/0.52s) Alternating Any T8 T19
T44 800/1000 @ 2Hz (0.25s/0.25s) Alternating Any T24 T19
T45 970/800 @ 2Hz (0.25s/0.25s) Alternating Any T8 T19
T46 800/1000 @ 0.875Hz (0.57s/0.57s) Alternating Any T24 T19
T47 2400/2900 @ 2Hz (0.25s/0.25s) Alternating Any T24 T19
T48 500/1200 @ 0.3Hz (1.67s/1.67s) Sweeping Any T24 T12
T49 560/1055 @ 0.18Hz (2.73s/2.73s) Sweeping Any T24 T12
T50 560/1055 @ 3.3Hz (0.15s/0.15s) Sweeping Any T24 T12
T51 600/1250 @ 0.125Hz (4s/4s) Sweeping Any T24 T12
T52 660/1200 @ 1Hz (0.50s/0.50s) Sweeping Any T24 T12
T53 800/1000 @ 1Hz (0.50s/0.50s) Sweeping Any T24 T12
T54 800/1000 @ 7Hz (0.07s/0.07s) Sweeping Any T24 T12
T55 800/1000 @ 50Hz (0.01s/0.01s) Sweeping Any T24 T12
T56 2400/2900 @ 7Hz (0.07s/0.07s) Sweeping Any T24 T12
T57 2400/2900 @ 1Hz (0.50s/0.50s) Sweeping Any T24 T12
T58 2400/2900 @ 50Hz (0.01s/0.01s) Sweeping Any T24 T12
T59 2500/3000 @ 2Hz (0.25s/0.25s) Sweeping Any T24 T12
T60 2500/3000 @ 7.7Hz (0.65s/0.65s) Sweeping Any T24 T12
T61 800Hz Motor Siren Any T24 T12
T62 1200Hz Motor Siren Any T24 T12
T63 2400Hz Motor Siren Any T24 T12
T64 Simulated Bell Any T21 T12
Country specific or custom tone configurations and alarm frequencies are available upon request.

Contact us
to discuss your gas detection needs today!

800-487-8450 or Click Here