AL105NX Alarm Horn Sounder & Xenon Strobe Beacon

The AL105NX is the industry standard for combined audible and visual signaling. The high output 113dB(A) alarm horn sounder is combined with a 5 Joule, 200cd Xenon strobe beacon. CPR complaint, EN54-3 & EN54-23 tested and UL/cUL approved for private mode fire use. Featuring 64 alarm tone frequencies and 4 remotely activated stages/channels.

DESCRIPTION
Globally approved for fire, marine and general applications the low current consumption and high SPL in a robust fire retardant enclosure ensure the AL105NX is suitable for all signalling applications including fire, security and process control. The alarm horn sounder & Xenon strobe beacon may be connected from a single or separate supplies for simultaneous or independent operation.
FEATURES
Automatic synchronisation
Continuously rated
Dual M20x1.5mm threaded cable entries - adaptors available
Duplicate pluggable cable terminations - Class A
Ingress protection IP66 Type 4/4X/13/3R
64 alarm tone frequencies and 4 remotely activated alarm stages
Available with custom tone configurations and frequencies
Diode polarized for use in supervised circuits
SPECIFICATION
Alarm Horn:
Maximum output: 113dB(A) @ 1 m ±3dB [104dB(A) @ 10ft/3m ±3dB]
Nominal output: 106dB(A) @ 1m ±3dB [97dB(A) @ 10ft/3m ±3dB]
No. of tones: 64 (UKOOA / PFEER compliant)
No. of stages: 4
Volume control: -12dB(A) tone dependent
Effective range: 58m/190ft @ 1KHz
In rush: 636mA within 4.0ms @ 24Vdc
Stage switching: Negative (common positive)
Xenon Strobe:
Energy: 5 Joules(5Ws)
Flash rate: 1Hz (60 fpm)
DC units: 1.5Hz (90 fpm) & Double strike
Peak Candela: 500,000 cd – calculated from energy (J)
Effective cd: 250 cd – calculated from energy (J)
Peak Candela: 86,935 cd* – measured ref. to I.E.S.
Effective cd: 200 cd* – measured ref. to I.E.S.
Tube life: Emissions may reduce to 70% after 8 million flashes
General:
Ingress protection: IP66 Type 4/4X/13/3R
Enclosure: High impact UL94 V0 & 5VA FR ABS/PC
Lens colour filter: Field replaceable UV stable PC
Terminals: 0.5 – 2.5mm² (20-14 AWG)
Line monitoring: Diode polarized for use in supervised circuits
Operating: -40 to +66°C [-40° to +151°F]
Storage: -40 to +70°C [-40° to +158°F]
Relative humidity: 95% at 20°C [68°F]
Vibration test: 35Hz for a duration 4Hr (UL464/UL1638)
Jarring test: 3ft/lb Energy (UL464/UL1638)
Impact test: 3x 5lb (UL464/UL1638)
MTBF DC: 114.79 years / 1,005,530 hours – MIL 217
MTBF AC: 86.29 years / 755,857 hours – MIL 217
Weight DC: 0.95kg / 2.10Ibs
Weight AC: 1.20kg / 2.64Ibs

Downloads

Datasheet
Installation Manual
UL certificate of compliance
CSFM Listing
EC CPR Certificate
UK CPR Certificate
UL EU Certificate EN54-3 EN54-23
Russian EAC Declaration of Conformity
Russian Maritime register
MED certificate
DNV MED Module D cert
DNV Type Approval
Declaration of Conformity
Declaration of Conformity UKCA
Declaration of Performance
2D drawing (PDF)
2D drawing (DWG)
3D drawing (STEP)
Wiring Schematic DC voltage
Wiring Schematic AC voltage

Photos / Media

Product Inquiries


Ask a Question, Get a Quote, or Report a Problem 
©2024 Conspec®. Website by
 Thinkr Marketing
©2024 Conspec®.
starstar-emptybookearthmagnifiercrossmenuchevron-down